    The National Grid: potential difference across primary coil x current in primary coil = potential difference across secondary coil x current in secondary coil

    The published AQA 8464 Combined Science specification includes this relationship for Higher Tier.

    • 3 key terms

    Study notes

    From the checked teaching notes for this specification point.

    The idea

    The published AQA 8464 Combined Science specification includes this relationship for Higher Tier. For a 100% efficient transformer, the electrical power entering the primary coil equals the electrical power leaving the secondary coil. Since power equals potential difference multiplied by current, Vₚ × Iₚ = Vₛ × Iₛ.

    For example: If Vₚ = 230 V, Iₚ = 4 A and Vₛ = 460 V, then Iₛ = (230 × 4) ÷ 460 = 2 A. A step-up transformer raises potential difference and lowers current for the same power; this lower current reduces thermal energy dissipation in National Grid cables.

    What earns the marks

    • States the ideal-transformer relationship Vₚ × Iₚ = Vₛ × Iₛ.
    • Identifies Vₚ and Iₚ as primary-coil quantities and Vₛ and Iₛ as secondary-coil quantities.
    • Substitutes values with volts and amperes consistently before rearranging for the unknown.
    • Explains that increasing potential difference reduces current when transmitted power is unchanged.
    • Links lower transmission current to reduced thermal energy dissipation in cables.

    Common mistakes and how to put them right

    • Pairing a primary potential difference with a secondary current.

      Put it right by keeping Vₚ with Iₚ and Vₛ with Iₛ.

    • Assuming a step-up transformer increases both potential difference and current.

      Put it right by using equal input and output power for an ideal transformer.

    • Dividing before writing the full equality.

      Put it right: Write VₚIₚ = VₛIₛ, substitute, then isolate the required quantity.

    Exam tips

    • Write VₚIₚ = VₛIₛ before substituting so each value stays attached to the correct coil.
    • Check the direction: a step-up transformer should give a lower secondary current for the same power.

    Try the lesson

    The start of the The National Grid: potential difference across primary coil x current in primary coil = potential difference across secondary coil x current in secondary coil lesson, made from checked teaching notes for this specification point.

    Have a go first

    Which equation correctly links the potential difference and current in the primary and secondary coils of a 100% efficient transformer?

    Listen

    The published AQA 8464 Combined Science specification includes this relationship for Higher Tier. For a 100% efficient transformer, the electrical power entering the primary coil equals the electrical power leaving the secondary coil. Since power equals potential difference multiplied by current, Vₚ × Iₚ = Vₛ × Iₛ. For example, if Vₚ = 230 V, Iₚ = 4 A and Vₛ = 460 V, then Iₛ = (230 × 4) ÷ 460 = 2 A. A step-up transformer raises potential difference and lowers current for the same power; this lower current reduces thermal energy dissipation in National Grid cables. A strong answer earns marks for these points. States the ideal-transformer relationship Vₚ × Iₚ = Vₛ × Iₛ. Identifies Vₚ and Iₚ as primary-coil quantities and Vₛ and Iₛ as secondary-coil quantities. Substitutes values with volts and amperes consistently before rearranging for the unknown. Explains that increasing potential difference reduces current when transmitted power is unchanged. A common slip: Pairing a primary potential difference with a secondary current. Instead, keeping Vₚ with Iₚ and Vₛ with Iₛ. Exam tip: Write VₚIₚ = VₛIₛ before substituting so each value stays attached to the correct coil.

    Key words

    Say what each word means before you turn the card.

    Ideal transformer power balance

    Try answering aloud or in your head before turning the card.

    Potential difference and current

    Try answering aloud or in your head before turning the card.

    National Grid efficiency

    Try answering aloud or in your head before turning the card.

    See every definition
    Ideal transformer power balance
    For a 100% efficient transformer, the electrical power entering the primary coil equals the electrical power leaving the secondary coil.
    Potential difference and current
    Power equals potential difference multiplied by current, so Vₚ × Iₚ = Vₛ × Iₛ for a 100% efficient transformer.
    National Grid efficiency
    A step-up transformer raises potential difference and lowers current for the same power, and this lower current reduces thermal energy dissipation in National Grid cables.

    There is more to this lesson

    The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.

    Carry on with the full lesson

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge

    Test your understanding of The National Grid: potential difference across primary coil x current in primary coil = potential difference across secondary coil x current in secondary coil

    Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.

    Take topic quiz

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge