The idea
This core practical requires you to perform a real titration, not just describe one. Rinse the burette with the acid it will contain, then fill it and remove air from the jet before reading the initial volume at eye level, bottom of the meniscus. Use a pipette filler to transfer a measured volume of alkali into a conical flask, add a suitable indicator such as phenolphthalein or methyl orange, and swirl. Add acid steadily, then dropwise near the end point, rinsing the flask walls with distilled water. Record the final burette reading and repeat until you obtain concordant titres, typically within 0.10 cm³. Accuracy depends on technique: no air bubbles, no parallax, correct indicator choice and consistent swirling.
What earns the marks
- Rinses the burette with the solution it will contain and fills it without air bubbles in the jet.
- Uses a pipette and pipette filler to deliver an accurate volume of alkali into a conical flask.
- Selects a suitable indicator and adds only a few drops, swirling to mix.
- Reads the burette at eye level at the bottom of the meniscus and records initial and final volumes to two decimal places.
- Adds acid dropwise near the end point and repeats the titration to obtain concordant titres.
Common mistakes and how to put them right
Rinsing the burette with water instead of the acid it will contain, which dilutes the acid and gives a falsely large titre.
Put it right: The burette should be rinsed with the solution it will hold.
Reading the burette from above or below eye level, causing parallax error.
Put it right: The reading must be taken at eye level at the bottom of the meniscus.
Adding indicator in large amounts rather than a few drops, which can shift the end point.
Put it right: Only two or three drops are needed.
Stopping after one titration.
Put it right: At least two concordant titres within about 0.10 cm³ are needed for accuracy.
Exam tips
- Learn the order of the method: rinse, fill, remove air, read initial volume, pipette alkali, add indicator, titrate, read final volume, repeat.
- Practise reading a burette diagram and calculating a titre by subtracting the initial reading from the final reading.
- Be ready to explain why each piece of apparatus is used: burette for variable accurate volumes, pipette for a fixed accurate volume, indicator to show the end point.
Try the lesson
The start of the Topic 5 – Separate chemistry 1: 5.9C Core Practical: Carry out an accurate acid-alkali titration, using burette, pipette and a suitable indicator lesson, made from teaching notes for this specification point.
Have a go first
A student titrates 25.0 cm³ of sodium hydroxide solution with hydrochloric acid, using a pipette to measure the alkali and a burette to add the acid. Which indicator is most suitable for detecting the end point of this titration?
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of Topic 5 – Separate chemistry 1: 5.9C Core Practical: Carry out an accurate acid-alkali titration, using burette, pipette and a suitable indicator
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge