    9.9C Evaluate data from a flame photometer

    Full specification wording

    Topic 9 – Separate chemistry 2: 9.9C Evaluate data from a flame photometer: a to determine the concentration of ions in dilute solution using a calibration curve b to identify metal ions by comparing the data with reference data (no knowledge of the instrument or how it works is required)

    A flame photometer is an instrumental method used to identify metal ions and determine their concentrations in dilute solutions.

    • Point 10 of 39

    Study notes

    From the teaching notes for this specification point.

    The idea

    A flame photometer is an instrumental method used to identify metal ions and determine their concentrations in dilute solutions. In this specification statement, no knowledge of the instrument mechanism is required; you must evaluate the resulting data. To determine the concentration of metal ions, a calibration curve is constructed by measuring the emission intensity of reference solutions of known concentrations and plotting intensity against concentration. The measured intensity of the unknown sample is then read off the calibration curve to find its concentration. To identify metal ions in a sample or mixture, the wavelengths of light emitted are compared with reference spectra of known ions; each element produces a characteristic set of emission lines, allowing individual ions in complex mixtures to be distinguished.

    What earns the marks

    • Construct a calibration curve by plotting emission intensity against known ion concentrations.
    • Determine unknown concentration by measuring its emission intensity and reading off the calibration curve.
    • Identify metal ions by comparing emitted light wavelengths/spectra with reference data.
    • Instrumental flame photometry can analyse mixtures of metal ions where flame test colours would overlap.
    • No knowledge of internal instrument mechanics is required.

    Common mistakes and how to put them right

    • Using a calibration curve made from a different metal ion to find a concentration.

      Put it right: The standards must contain the same ion as the unknown, otherwise the comparison is invalid.

    • Assuming the reading is directly proportional to concentration without checking the curve.

      Put it right: Read from the plotted line of best fit instead of doubling or halving by eye.

    • Confusing the two tasks.

      Put it right: Identification matches the unknown to reference data for a known ion, while concentration determination uses a calibration curve of readings against known concentrations.

    Exam tips

    • Check whether the question asks you to identify an ion or to determine a concentration, and choose the matching method.
    • When reading a calibration curve, show the two construction lines from the unknown reading to the curve and then to the concentration axis.
    • Give the concentration with its unit, for example mol dm⁻³, and quote the value to the precision the graph allows.

    Try the lesson

    The start of the Topic 9 – Separate chemistry 2: 9.9C Evaluate data from a flame photometer: a to determine the concentration of ions in dilute solution using a calibration curve b to identify metal ions by comparing the data with reference data (no knowledge of the instrument or how it works is required) lesson, made from teaching notes for this specification point.

    Have a go first

    A calibration curve for potassium ions gives readings of 0, 15, 30 and 60 for solutions of 0, 1, 2 and 4 mg/dm³ respectively. An unknown potassium solution gives a reading of 45. Using the calibration curve, which value is closest to the concentration of potassium ions in the unknown solution?

    There is more to this lesson

    The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.

    Carry on with the full lesson

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge

    Test your understanding of Topic 9 – Separate chemistry 2: 9.9C Evaluate data from a flame photometer: a to determine the concentration of ions in dilute solution using a calibration curve b to identify metal ions by comparing the data with reference data (no knowledge of the instrument or how it works is required)

    Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.

    Take topic quiz

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge