Pearson Edexcel · A-Level · Physics
Course version: 9PH0 · Version from Sept 2015
Electric Circuits: 46. CORE PRACTICAL 3: Determine the e.m.f. and internal…
Full specification wording
Topic 3: Electric Circuits: 46. CORE PRACTICAL 3: Determine the e.m.f. and internal resistance of an electrical cell.
Core Practical 3 asks you to measure a cell's e.m.f. ε and internal resistance r by varying the current drawn and recording terminal p.d.
- Point 16 of 16
Study notes
From the teaching notes for this specification point.
The idea
Core Practical 3 asks you to measure a cell's e.m.f. ε and internal resistance r by varying the current drawn and recording terminal p.d. V. Build the circuit with the cell, a variable resistor, an ammeter in series and a voltmeter across the cell terminals. For each setting record I and V, then plot V against I. Because V = ε − Ir, the graph is a straight line of gradient −r and intercept ε on the V-axis. Take several readings across a wide current range, use a switch to avoid draining the cell, and keep connections tight. Recognise that the terminal p.d. falls as current rises because energy is dissipated inside the cell; the lost volts equal Ir. Assess uncertainty by considering meter resolution and the scatter of points about the line of best fit.
What earns the marks
- States the working equation V = ε − Ir and identifies the intercept of the V–I graph as the e.m.f. ε.
- Identifies the gradient of the V–I graph as −r, so internal resistance r is the magnitude of the gradient.
- Describes a valid circuit: cell, variable resistor, ammeter in series, voltmeter in parallel across the cell terminals.
- Explains that terminal p.d. decreases with increasing current because the lost volts Ir increase inside the cell.
- Selects a method of analysis: plot V against I, draw a line of best fit, read intercept and gradient.
- Recognises the need for several readings over a range of currents and a switch to limit cell heating/drainage.
Common mistakes and how to put them right
Plotting I against V and then reading the gradient as r directly.
Put it right: Plot V against I so the gradient is −r and the intercept is ε.
Assuming the voltmeter reads e.m.f. at all times.
Put it right: The voltmeter reads terminal p.d., which equals ε only when current is negligible.
Treating internal resistance as external circuit resistance.
Put it right: r is inside the cell and causes lost volts Ir, reducing terminal p.d. below ε.
Exam tips
- Always state which quantity is on each axis before describing how to find ε and r.
- Link the gradient sign to the equation: a negative gradient of magnitude r follows from V = ε − Ir.
- Mention practical precautions such as a switch and a wide current range to improve the line of best fit.
Try the lesson
The start of the Topic 3: Electric Circuits: 46. CORE PRACTICAL 3: Determine the e.m.f. and internal resistance of an electrical cell. lesson, made from teaching notes for this specification point.
Have a go first
A student varies an external resistor connected to a cell and plots a straight-line graph of terminal potential difference V (vertical axis) against current I (horizontal axis). Which quantity is given by the vertical-axis intercept of this line, where I = 0?
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of Topic 3: Electric Circuits: 46. CORE PRACTICAL 3: Determine the e.m.f. and internal resistance of an electrical cell.
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge