Skip to topic
    ← Back to course topics

    Absorption of X-rays (A-level only) — AQA A-Level Physics

    Teaching note checked against the official specification.

    Absorption of X-rays occurs when photons are removed from a beam as they pass through matter, primarily via the photoelectric effect and Compton scattering. The intensity decreases exponentially with thickness according to I = I0 e^(-mu x), where mu is the linear attenuation coefficient, a key concept for medical imaging and radiation safety.

    Test yourself on Absorption of X-rays (A-level only) with AQA A-Level practice questions.

    Start free

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge

    Absorption of X-rays (A-level only) explained

    When a narrow beam of X-rays passes through matter, photons are removed by absorption and scattering, so the beam intensity falls.

    Read the full explanation

    Because each thin layer removes a constant fraction of the photons still present, the decrease is exponential rather than linear. The transmitted intensity I after thickness x is I = I₀e^(−μx), where I₀ is the incident intensity and μ is the attenuation coefficient, measured in m⁻¹. A larger μ or a thicker absorber gives a smaller I. Taking natural logarithms gives ln I = ln I₀ − μx, so a graph of ln I against x is a straight line of gradient −μ. The half-value thickness x½, where I = I₀/2, is related to μ by x½ = ln 2 / μ. This explains why radiographers choose photon energies and shielding thicknesses carefully.

    Read the Absorption of X-rays (A-level only) study guideFull revision notes for AQA A-Level Physics

    Your focus

    1. Describe how the intensity of a narrow X-ray beam changes as it passes through an absorber.
    2. Apply I = I₀e^(−μx) and ln I = ln I₀ − μx to solve numerical and graphical problems.
    3. Determine μ and half-value thickness from experimental data and interpret their physical meaning.

    Which command word is this?

    You must use the given data and the correct formula to find a numerical answer. Show all steps, include units, and give your answer to an appropriate number of significant figures. Marks are awarded for correct substitution and final answer.

    Absorption of X-rays (A-level only) exam tips

    Topic Overview

    This topic covers how X-ray photons are removed from a beam as they pass through matter, focusing on the exponential attenuation law I = I0 e^(-mu x). You will learn the three main interaction mechanisms: the photoelectric effect, Compton scattering, and pair production, and how their relative importance depends on photon energy and the atomic number of the absorber. Understanding these processes is essential for explaining why different materials are used for shielding and why contrast agents such as barium and iodine are used in medical imaging.

    The concept of absorption of X-rays is fundamental to medical physics, radiography, and radiation protection. It builds on your knowledge of photon energy (E = hf), the photoelectric effect, and atomic structure. In AQA A-Level Physics, this topic often appears in the Medical Physics option and in questions about attenuation calculations, half-value thickness, and the design of X-ray machines and shields.

    Key Concepts
    • →The intensity of a collimated X-ray beam decreases exponentially with thickness: I = I0 e^(-mu x), where mu is the linear attenuation coefficient (units m^-1 or cm^-1).
    • →The linear attenuation coefficient mu depends on the photon energy and the absorber's atomic number and density; it is the sum of contributions from photoelectric absorption, Compton scattering, and pair production.
    • →The photoelectric effect dominates at low photon energies and for high-Z materials; it is proportional to Z^3 and E^-3, making lead an excellent shield for diagnostic X-rays.
    • →Compton scattering dominates at higher energies (around 0.1-10 MeV) and depends on the electron density of the material, not strongly on Z.
    • →Half-value thickness (HVT) is the thickness of material required to reduce the intensity to half its original value; it is related to mu by HVT = ln(2)/mu.
    Marking Points
    • States that intensity decreases exponentially with absorber thickness because each equal layer removes the same fraction of the photons remaining.
    • Recalls and applies I = I₀e^(−μx), identifying I₀ as incident intensity, I as transmitted intensity, μ as attenuation coefficient and x as thickness.
    • Uses the linear form ln I = ln I₀ − μx to find μ from the gradient of a graph of ln I against x.
    • Calculates half-value thickness from x½ = ln 2 / μ and explains that it is independent of the initial intensity.
    • Explains that μ depends on the material and on photon energy, so comparison of absorbers requires like-for-like conditions.
    • Interprets a steeper exponential curve or larger gradient as a larger attenuation coefficient and therefore a more strongly attenuating material.
    Examiner Tips
    • 💡Write the exponential equation before substituting numbers, then rearrange symbolically so the examiner can follow your method.
    • 💡When a graph of ln I against x is given, read the gradient from well-separated points on the line of best fit and quote μ with the unit m⁻¹.
    • 💡Check that your answer for transmitted intensity is less than the incident intensity; a value greater than I₀ signals a sign or rearrangement error.
    • 💡Link each calculation back to the physical situation, for example stating that a larger μ means more photons are removed per metre.
    • 💡Always show your working clearly in attenuation calculations: write the formula, substitute numbers with units, and give your answer to an appropriate number of significant figures (usually 2 or 3).
    • 💡When explaining why a material is a good shield, refer to both the photoelectric effect and Compton scattering, and state how each depends on atomic number and photon energy.
    • 💡In questions about medical imaging, link the absorption of X-rays to the contrast between bone and soft tissue, and explain how contrast agents increase absorption by providing high-Z atoms.
    Common Mistakes
    • Treating attenuation as linear and subtracting a fixed intensity for each centimetre; the correct model is a constant fractional decrease, giving an exponential curve.
    • Using logarithms to base ten when the equation is written with e; either use natural logarithms throughout or convert the coefficient consistently.
    • Forgetting to convert thickness to metres before dividing by μ, which gives a value of μ in the wrong unit; convert mm or cm to m first.
    • Assuming half-value thickness depends on I₀; it is fixed by μ alone, so doubling the incident intensity does not change x½.
    • Students often think that X-rays are completely absorbed by a material once they exceed a certain thickness. In reality, absorption is exponential, so the intensity never reaches zero, though it becomes negligible after several half-value thicknesses.
    • Many students believe that the linear attenuation coefficient mu is a constant for a given material. It actually depends strongly on the photon energy, so mu changes with the X-ray tube voltage (kVp).
    • Some students confuse the linear attenuation coefficient (mu) with the mass attenuation coefficient (mu/rho). The mass attenuation coefficient is independent of density and is often tabulated; to find mu, you must multiply by the density.
    Revision Plan
    1. 1Day 1: Review the exponential attenuation law and learn the definitions of linear attenuation coefficient, half-value thickness, and mass attenuation coefficient. Practice rearranging I = I0 e^(-mu x) to solve for mu, x, or I.
    2. 2Day 2: Study the three interaction mechanisms (photoelectric, Compton, pair production) and create a table comparing their dependence on photon energy and atomic number. Use your textbook or reliable online resources.
    3. 3Day 3: Work through calculations involving half-value thickness and attenuation, including converting between mu and mu/rho. Attempt past paper questions on these calculations.
    4. 4Day 4: Practice explanation questions: why lead is used for shielding, why contrast agents are used, and how the absorption of X-rays produces an image. Write model answers and check against mark schemes.
    5. 5Day 5: Complete a timed past paper section on this topic, then review your mistakes and revisit any weak areas. Use active recall to test yourself on key definitions and formulas.
    Exam Question Types
    • 📋Calculation of transmitted intensity or thickness using I = I0 e^(-mu x). Advice: always convert units to be consistent and check the exponent is dimensionless.
    • 📋Explanation of why a particular material is suitable for shielding or contrast, linking to photoelectric effect and Compton scattering. Advice: mention Z^3 dependence and energy dependence.
    • 📋Graph interpretation: given a graph of ln(I) against x, determine mu from the gradient. Advice: remember that ln(I) = ln(I0) - mu x, so gradient = -mu.
    • 📋Comparison of the effectiveness of different materials or thicknesses for X-ray attenuation. Advice: use the concept of half-value thickness and consider the energy of the X-rays.
    Command Word Expectations (AQA)
    Calculate

    You must use the given data and the correct formula to find a numerical answer. Show all steps, include units, and give your answer to an appropriate number of significant figures. Marks are awarded for correct substitution and final answer.

    Explain

    You must give reasons or mechanisms for a phenomenon, using correct physics terminology. For example, explain why lead attenuates X-rays more than aluminium by referring to the photoelectric effect and its Z^3 dependence. A simple statement is not enough; you need a logical chain of reasoning.

    Describe

    You must give a detailed account of the process or properties, without necessarily giving reasons. For example, describe how the intensity of an X-ray beam changes as it passes through a material, mentioning exponential decrease and the role of attenuation mechanisms.

    How Students Lose Marks (Examiner Pitfalls)
    Pitfall: Students often confuse the linear attenuation coefficient (mu) with the mass attenuation coefficient (mu/rho) and fail to convert units correctly, leading to order-of-magnitude errors in calculations.
    ❌ Weak Answer (Loses Marks):Using mu = 0.2 cm^-1 directly with thickness in metres without converting, giving an incorrect intensity ratio.
    Example improved answer:First convert all lengths to the same unit, typically metres or centimetres. If mu is given in cm^-1, convert thickness to cm. Then apply I = I0 e^(-mu x). For example, if mu = 0.2 cm^-1 and x = 5 cm, I/I0 = e^(-0.2*5) = e^-1 = 0.37, so 37% is transmitted.
    Examiner Tip: Always write down the units of mu and x before substituting. Convert to consistent units (e.g., both in cm or both in m) and check that the exponent is dimensionless.
    Pitfall: Students frequently state that X-ray absorption is due to the photoelectric effect alone, ignoring Compton scattering and pair production, and fail to explain how absorption depends on atomic number and photon energy.
    ❌ Weak Answer (Loses Marks):X-rays are absorbed because they hit atoms and are stopped. Higher atomic number means more absorption.
    Example improved answer:X-ray attenuation occurs via three main mechanisms: the photoelectric effect (dominant at low energies and high Z), Compton scattering (dominant at higher energies, depends on electron density), and pair production (only above 1.02 MeV). The photoelectric effect is proportional to Z^3 and E^-3, so materials with high atomic number such as lead are effective shields, especially for lower-energy X-rays. Compton scattering is roughly proportional to electron density and is less dependent on Z.
    Examiner Tip: When asked to explain absorption, always mention at least two mechanisms and how they depend on photon energy and the absorber's atomic number. Use the correct terminology: attenuation, photoelectric effect, Compton scattering.
    Step-by-Step Worked Solutions

    Question: A monochromatic X-ray beam of initial intensity I0 passes through an aluminium sheet of thickness 2.0 mm. The linear attenuation coefficient of aluminium for this X-ray energy is 0.50 mm^-1. Calculate the fraction of the incident intensity transmitted. If the initial intensity is 4.0 x 10^4 W m^-2, what is the transmitted intensity?

    1. 1.Step 1: Identify given values: mu = 0.50 mm^-1, x = 2.0 mm, I0 = 4.0 x 10^4 W m^-2.
    2. 2.Step 2: Use the exponential attenuation formula: I = I0 e^(-mu x).
    3. 3.Step 3: Calculate exponent: mu x = 0.50 * 2.0 = 1.0 (dimensionless).
    4. 4.Step 4: Calculate transmitted fraction: I/I0 = e^-1.0 = 0.3679 (to 4 s.f.).
    5. 5.Step 5: Calculate transmitted intensity: I = 4.0 x 10^4 * 0.3679 = 1.47 x 10^4 W m^-2.
    Final Answer: Transmitted fraction = 0.37 (37%); transmitted intensity = 1.5 x 10^4 W m^-2 (2 s.f.).

    Question: Explain why lead is a more effective shield against X-rays than aluminium, and why a thin sheet of lead may be less effective than a thicker sheet of aluminium for very high energy X-rays.

    1. 1.Step 1: State that attenuation depends on the photoelectric effect, which is proportional to Z^3, so lead (Z=82) absorbs much more strongly than aluminium (Z=13) at typical diagnostic energies.
    2. 2.Step 2: Note that at very high energies, the photoelectric effect becomes negligible and Compton scattering dominates; Compton scattering depends on electron density, not Z.
    3. 3.Step 3: Compare electron densities: lead has higher electron density, but the difference is less dramatic than Z^3. Also, a thicker sheet of aluminium provides more scattering centres.
    4. 4.Step 4: Conclude that for high energy X-rays, a thick aluminium sheet can attenuate as much as a thin lead sheet because the dominant mechanism is Compton scattering, which depends on the number of electrons per unit area.
    Final Answer: Lead is better at low energies due to Z^3 dependence of photoelectric absorption; at high energies, Compton scattering dominates and depends on electron density, so thickness and electron density matter more than atomic number alone.
    Active Recall Memory Test
    State the equation for the exponential attenuation of X-rays and define each term.
    Key Fact: I = I0 e^(-mu x), where I is transmitted intensity, I0 is initial intensity, mu is the linear attenuation coefficient, and x is the thickness of the absorber.
    What is the half-value thickness and how is it related to the linear attenuation coefficient?
    Key Fact: Half-value thickness (HVT) is the thickness of material required to reduce the intensity of an X-ray beam to half its original value. It is given by HVT = ln(2)/mu.
    Name the three main mechanisms by which X-rays are attenuated in matter and state how each depends on atomic number and photon energy.
    Key Fact: Photoelectric effect: proportional to Z^3 and E^-3. Compton scattering: proportional to electron density, weakly dependent on Z, decreases with increasing energy. Pair production: occurs only above 1.02 MeV, proportional to Z^2 and increases with energy.
    Why is lead used as a shielding material for X-rays?
    Key Fact: Lead has a high atomic number (Z=82), so the photoelectric effect is very strong (proportional to Z^3), making it highly effective at absorbing X-rays, especially at lower energies. It is also dense, providing a high electron density for Compton scattering.
    Frequently Asked Questions
    What is the difference between linear attenuation coefficient and mass attenuation coefficient?
    The linear attenuation coefficient (mu) measures the probability of attenuation per unit length and depends on the density of the material. The mass attenuation coefficient (mu/rho) is the linear attenuation coefficient divided by the density, so it is independent of the physical state of the material and is often tabulated for different photon energies. To find mu, multiply the mass attenuation coefficient by the density.
    How do you calculate the thickness of material needed to reduce X-ray intensity by a certain factor?
    Use the exponential attenuation equation I = I0 e^(-mu x). Rearrange to solve for x: x = (1/mu) * ln(I0/I). For example, to reduce intensity to 10% of its original value, I0/I = 10, so x = ln(10)/mu. Ensure that mu and x have consistent units.
    Why does the absorption of X-rays depend on the atomic number of the material?
    The photoelectric effect, which is a major absorption mechanism especially at lower energies, is proportional to Z^3. This means that materials with higher atomic number, such as lead or barium, absorb X-rays much more strongly than low-Z materials like aluminium or soft tissue. Compton scattering, on the other hand, depends on electron density and is less sensitive to Z.
    What is half-value thickness and how is it used in radiography?
    Half-value thickness (HVT) is the thickness of a material that reduces the X-ray intensity by half. It is used to compare the shielding effectiveness of different materials and to calculate the thickness needed to reduce radiation to safe levels. In radiography, it helps determine exposure times and filter thicknesses to optimise image quality while minimising patient dose.
    How does the energy of X-rays affect their absorption in bone versus soft tissue?
    At lower X-ray energies (around 20-50 keV), the photoelectric effect dominates and is strongly dependent on atomic number. Bone contains calcium (Z=20) and has a higher effective atomic number than soft tissue (mainly water, Z_eff ~7.5), so bone absorbs X-rays much more strongly, creating good contrast. At higher energies, Compton scattering dominates and contrast between bone and soft tissue decreases because Compton scattering depends mainly on electron density, which is similar for bone and soft tissue.
    Why are contrast agents like barium or iodine used in X-ray imaging?
    Contrast agents contain high atomic number elements (barium Z=56, iodine Z=53) which strongly absorb X-rays via the photoelectric effect. When introduced into the body, they increase the attenuation of X-rays in specific areas, such as the digestive tract or blood vessels, making these structures visible against surrounding soft tissue. This improves diagnostic accuracy.