OCR · GCSE · Chemistry
Course version: J248 · Version from Sept 2018
Use of appropriate apparatus to make and record a range of measurements…
Full specification wording
Measuring rates of reaction: Use of appropriate apparatus to make and record a range of measurements accurately, including mass, time, temperature, and volume of liquids and gases
Measuring a rate of reaction needs accurate readings of mass, time, temperature and volume.
- Point 1 of 2
Study notes
From the teaching notes for this specification point.
The idea
Measuring a rate of reaction needs accurate readings of mass, time, temperature and volume. Mass loss is measured with a balance, often on a top-pan balance as gas escapes. Time is measured with a stopwatch or timer, started and stopped at defined points. Temperature is measured with a thermometer or temperature probe. Liquid volume is measured with a measuring cylinder, burette or pipette, choosing the most precise for the task. Gas volume is measured with a gas syringe or by collecting over water. Accuracy means reading at eye level, using the correct scale, and recording to the precision of the instrument. Questions ask which apparatus suits a measurement and how to record it accurately.
What earns the marks
- Selects a balance for measuring mass, including mass lost as gas escapes.
- Selects a stopwatch or timer for measuring time and states defined start and stop points.
- Selects a thermometer or temperature probe for measuring temperature.
- Selects a measuring cylinder, burette or gas syringe for measuring the volume of a liquid or gas.
- Records readings to the precision of the instrument and reads scales at eye level.
Common mistakes and how to put them right
Uses a thermometer to measure liquid volume.
Put it right: Select a measuring cylinder or burette for volume.
Records a balance reading to more decimal places than the instrument shows.
Put it right: Record to the precision of the scale.
Starts timing before the reactants are mixed.
Put it right: Start the timer at the moment the reactants meet.
Exam tips
- Match each measurement to its named apparatus before answering.
- Check the scale and read at eye level to avoid parallax error.
- State the start and stop points when time is measured so the rate is comparable.
Try the lesson
The start of the Measuring rates of reaction: Use of appropriate apparatus to make and record a range of measurements accurately, including mass, time, temperature, and volume of liquids and gases lesson, made from teaching notes for this specification point.
Have a go first
A student measures the volume of gas given off in a reaction every 20 seconds using a gas syringe. Which piece of apparatus is best for measuring the time intervals accurately?
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of Measuring rates of reaction: Use of appropriate apparatus to make and record a range of measurements accurately, including mass, time, temperature, and volume of liquids and gases
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge