Measuring rates of reaction — OCR GCSE Chemistry
Measuring rates of reaction explained
Measuring rates of reaction covers 2 specification points, including Use of appropriate apparatus to make and… and Making and recording of appropriate….
Read the full explanation
Open a point below for its explanation and revision guidance.
Use of appropriate apparatus to make and record a range of measurements accurately, including mass, time, temperature, and volume of liquids and gases
Measuring a rate of reaction needs accurate readings of mass, time, temperature and volume. Mass loss is measured with a balance, often on a top-pan balance as gas escapes. Time is measured with a stopwatch or timer, started and stopped at defined points. Temperature is measured with a thermometer or temperature probe. Liquid volume is measured with a measuring cylinder, burette or pipette, choosing the most precise for the task. Gas volume is measured with a gas syringe or by collecting over water. Accuracy means reading at eye level, using the correct scale, and recording to the precision of the instrument. Questions ask which apparatus suits a measurement and how to record it accurately.
Making and recording of appropriate observations during chemical reactions including changes in temperature and the measurement of rates of reaction by a variety of methods such as production of gas and colour change
This practical activity develops the skill of choosing and recording observations that actually show a reaction is happening, then using them to measure how fast it goes. For a temperature change, you record the thermometer reading at the start and at fixed time intervals, noting the direction and size of change rather than writing 'got hot'. For gas production, you can collect the gas in a syringe or inverted measuring cylinder and record the volume at set times, or record the mass lost as gas escapes from an open flask on a balance. For a colour change, you time how long a cross viewed through the solution takes to disappear, or compare colour intensity against a standard. In every method you record the measurement, its unit and the time, keep other variables controlled, and repeat readings to check reliability.
Your focus
- Select appropriate apparatus for measuring mass, time, temperature and volume
- Read and record measurements accurately to the precision of the instrument
- Explain how measurements are used to follow the rate of a reaction
Show all 6 objectives
- Select a measurable observation that shows a chemical reaction is occurring.
- Describe a method for following a reaction by temperature change, gas production or colour change.
- Explain how recorded readings at time intervals allow a rate of reaction to be determined.
Measuring rates of reaction exam tips
Marking Points
- Selects a balance for measuring mass, including mass lost as gas escapes
- Selects a stopwatch or timer for measuring time and states defined start and stop points
- Selects a thermometer or temperature probe for measuring temperature
- Selects a measuring cylinder, burette or gas syringe for measuring the volume of a liquid or gas
- Records readings to the precision of the instrument and reads scales at eye level
- States that a suitable observation is a measured quantity, such as temperature, gas volume, mass lost or time for a colour change, recorded with its unit.
- Explains that readings are taken at regular time intervals so that a rate can be calculated from how the measurement changes with time.
- Identifies that gas production can be followed by collecting gas in a syringe or measuring cylinder, or by measuring mass lost from an open flask.
- Describes that a colour change can be followed by timing how long a cross takes to disappear or by comparing intensity with a standard.
- Recognises that other variables, such as concentration, temperature and particle size, must be controlled so the rate comparison is fair.
- Selects an observation that is measurable and repeatable rather than a vague description such as 'it fizzed a lot'.
Examiner Tips
- 💡Match each measurement to its named apparatus before answering
- 💡Check the scale and read at eye level to avoid parallax error
- 💡State the start and stop points when time is measured so the rate is comparable
- 💡Link each observation to a quantity you can measure, and name the unit you would record.
- 💡When asked how to measure rate, describe the measurement taken and how often it is taken.
- 💡Explain why repeats or controlled variables make the rate comparison reliable.
- 💡Read the question carefully: it may ask for the observation, the method, or the reason, and each needs a different answer.
Common Mistakes
- Uses a thermometer to measure liquid volume; select a measuring cylinder or burette for volume
- Records a balance reading to more decimal places than the instrument shows; record to the precision of the scale
- Starts timing before the reactants are mixed; start the timer at the moment the reactants meet
- Records a vague description such as 'it bubbled' instead of a measured volume with a unit; record the actual gas volume at each time.
- Measures a colour change without timing it; record the time taken for the colour to change so a rate can be found.
- Changes two variables at once, for example concentration and temperature; keep all but one variable constant.
- Omits units from recorded readings; always state the unit, such as cm³, g or °C.