A transformer changes the size of an alternating voltage using two coils linked by a soft iron core. For an ideal transformer, the ratio of secondary to primary voltage equals the ratio of secondary to primary turns, so V_s/V_p = N_s/N_p, and power is conserved so V_p I_p = V_s I_s.
Test yourself on The operation of a transformer (A-level only) with AQA A-Level practice questions.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
The operation of a transformer (A-level only) explained
The operation of a transformer (A-level only) covers 2 specification points, including Causes of inefficiencies in a transformer.
Read the full explanation
and Transmission of electrical power at high…. Open a point below for its explanation and revision guidance.
Causes of inefficiencies in a transformer.
An ideal transformer transfers all input power to the output, so input power equals output power. Real transformers are less than 100% efficient because some energy is dissipated. The main causes are: resistance in the primary and secondary coils, which causes heating (I²R losses); eddy currents induced in the iron core, which circulate and heat the core; magnetic hysteresis in the core, where energy is needed to repeatedly magnetise and demagnetise the iron; and flux leakage, where some magnetic field lines do not link both coils. Efficiency is output power divided by input power, often expressed as a percentage. For example, if a transformer supplies 92 W from a 100 W input, efficiency is 92%. Laminated cores reduce eddy currents, and soft iron reduces hysteresis.
Transmission of electrical power at high voltage including calculations of power loss in transmission lines.
Electrical power is transmitted through cables that have resistance, so some energy is dissipated as heat. For a given power P transmitted at voltage V, the current is I = P ÷ V. The power lost in the transmission line of resistance R is P_loss = I²R. Because P_loss depends on I², increasing the transmission voltage reduces the current and greatly reduces power loss. Transformers step up voltage for transmission and step down voltage for safe domestic use. For example, transmitting 10 MW at 250 kV gives I = 40 A; if R = 5 Ω, P_loss = (40 A)² × 5 Ω = 8000 W. At 25 kV the current would be 400 A and the loss would be 800 kW, showing the benefit of high-voltage transmission.
Your focus
- Identify and describe the main causes of inefficiency in a transformer.
- Calculate transformer efficiency from input and output power.
- Relate transformer design features to the reduction of specific energy losses.
Show all 6 objectives
- Use P = VI and P_loss = I²R to calculate current and power loss in transmission lines.
- Explain why electrical power is transmitted at high voltage.
- Evaluate the effect of changing transmission voltage on power loss for a fixed transmitted power.
Which command word is this?
A brief answer with no explanation required. For example, 'State the function of the core in a transformer' expects 'To link the magnetic flux between the primary and secondary coils' or 'To provide a path for the magnetic flux'.
The operation of a transformer (A-level only) exam tips
Topic Overview
This topic covers how a transformer uses electromagnetic induction to change the size of an alternating voltage. You need to understand the construction of a transformer, including the primary and secondary coils and the laminated soft iron core, and how a changing magnetic flux in the core induces an e.m.f. in the secondary coil. The key equations are the turns ratio equation (V_s/V_p = N_s/N_p) and the power conservation equation for an ideal transformer (V_p I_p = V_s I_s).
Transformers are essential in the national grid for transmitting electrical power at high voltages to reduce energy losses, and in many everyday devices to step down voltage to safe levels. This topic links directly to electromagnetic induction, Faraday's law, and Lenz's law, and it is a common context for exam questions on efficiency and power losses. Understanding transformers also helps you appreciate why a.c. is used for power distribution rather than d.c.
Key Concepts
- →A transformer consists of two coils (primary and secondary) wound on a laminated soft iron core. An alternating current in the primary coil produces a changing magnetic flux in the core, which links the secondary coil and induces an alternating e.m.f. across it.
- →For an ideal transformer, the ratio of secondary voltage to primary voltage equals the ratio of secondary turns to primary turns: V_s/V_p = N_s/N_p. This means a step-up transformer has more turns on the secondary coil, and a step-down transformer has fewer.
- →In an ideal transformer, power is conserved: V_p I_p = V_s I_s. Therefore, if voltage is stepped up, current is stepped down, and vice versa.
- →Real transformers are not 100% efficient. Energy losses occur due to resistance heating in the coils, eddy currents induced in the core, and hysteresis losses as the core magnetises and demagnetises. These are reduced by using thick copper wires, a laminated core, and a soft magnetic material.
- →Transformers only work with alternating current (or a changing direct current) because a changing magnetic flux is required to induce an e.m.f. A steady direct current produces a constant flux and no induced e.m.f.
Marking Points
- Resistance in the primary and secondary coils causes heating, often called I²R or copper losses.
- Eddy currents are induced in the core by changing magnetic flux and dissipate energy as heat.
- Hysteresis losses occur because energy is required to magnetise and demagnetise the core each cycle.
- Flux leakage occurs when some magnetic field lines from the primary do not link the secondary coil.
- Efficiency = (output power ÷ input power) × 100%, and real efficiency is always less than 100%.
- Laminated cores reduce eddy currents; soft magnetic materials reduce hysteresis losses.
- Power transmitted is related to voltage and current by P = VI, so I = P ÷ V.
- Power loss in a transmission line of resistance R is P_loss = I²R.
- For a fixed transmitted power, increasing voltage decreases current and therefore decreases power loss.
- Transformers are used to step up voltage for transmission and step down voltage for distribution and domestic use.
- Calculations may require combining P = VI with P_loss = I²R to find current, resistance or lost power.
- The efficiency of transmission can be found from useful output power divided by input power, often as a percentage.
Examiner Tips
- 💡When asked for causes, name the mechanism and state the energy transfer, for example eddy currents transfer energy by heating the core.
- 💡Use the efficiency equation with consistent power units and give the answer as a percentage when appropriate.
- 💡Link each cause to a practical design feature, such as laminated core for eddy currents or soft iron for hysteresis.
- 💡Write down the transmitted power and the line resistance before substituting into equations.
- 💡Show the current calculation separately so that an error in squaring does not lose all method marks.
- 💡State clearly that high voltage reduces current, and link this to reduced heating in the cables.
- 💡Always state that the transformer relies on electromagnetic induction and that a changing magnetic flux is essential. Mention that the core is laminated to reduce eddy currents and made of soft iron to reduce hysteresis losses.
- 💡When calculating with the transformer equation, write down the equation clearly and substitute values carefully. Check whether the transformer is step-up or step-down by comparing turns.
- 💡For efficiency questions, use the formula: efficiency = (useful power output / total power input) x 100%. Remember that power input = V_p I_p and power output = V_s I_s for an ideal transformer, but for a real transformer, output power is less than input power.
Common Mistakes
- Thinking that a transformer creates energy or that output power can exceed input power; correct by applying conservation of energy so output power is always less than input power in a real transformer.
- Confusing eddy currents with the current in the coils; correct by stating that eddy currents are induced within the core itself and cause heating.
- Ignoring flux leakage and attributing all inefficiency to resistance; correct by listing flux leakage as a separate cause where magnetic field lines fail to link both coils.
- Using P_loss = V²R instead of P_loss = I²R; correct by using the current in the line and the line resistance.
- Assuming that increasing voltage increases power loss; correct by explaining that for fixed transmitted power, higher voltage means lower current and lower I²R loss.
- Forgetting to square the current in P_loss = I²R; correct by calculating the current first and then squaring it before multiplying by resistance.
- Students often think a step-up transformer increases power. In fact, for an ideal transformer, power is conserved; the voltage increases but the current decreases proportionally.
- Students sometimes believe transformers work with direct current. They only work with alternating current because a changing magnetic flux is needed to induce an e.m.f. in the secondary coil.
- Students may confuse the turns ratio with the current ratio. Remember: V_s/V_p = N_s/N_p, but I_s/I_p = N_p/N_s.
Revision Plan
- 1Start by reviewing electromagnetic induction and Faraday's law. Make sure you understand how a changing magnetic field induces an e.m.f. in a coil.
- 2Learn the construction of a transformer and the function of each part (primary coil, secondary coil, laminated soft iron core). Draw a labelled diagram and annotate it.
- 3Memorise and practise using the transformer equations: V_s/V_p = N_s/N_p and V_p I_p = V_s I_s. Solve numerical problems, including efficiency calculations.
- 4Study the causes of energy losses in a transformer and how they are reduced. Make a table of loss mechanism and method of reduction.
- 5Attempt past paper questions on transformers, focusing on explanations and calculations. Mark your answers using the mark scheme and note recurring mistakes.
Exam Question Types
- 📋Calculation questions: Use the turns ratio equation to find an unknown voltage or number of turns, or use power conservation to find current. Always show your working and give units.
- 📋Explanation questions: Describe how a transformer works, why it needs a.c., and how energy losses are reduced. Use key terms like 'changing magnetic flux', 'induced e.m.f.', 'laminated core', and 'eddy currents'.
- 📋Efficiency and power loss questions: Calculate efficiency or power lost, and explain how real transformers are made more efficient. Remember to use power in = power out + losses.
- 📋Graph or data analysis: Interpret a graph of voltage against time for primary and secondary coils, or analyse data on efficiency. Relate the shape of the graph to the alternating nature of the input.
Command Word Expectations (AQA)
A brief answer with no explanation required. For example, 'State the function of the core in a transformer' expects 'To link the magnetic flux between the primary and secondary coils' or 'To provide a path for the magnetic flux'.
You must give reasons or mechanisms. For example, 'Explain why a transformer cannot work with direct current' requires a statement that a changing magnetic flux is needed to induce an e.m.f., and a steady d.c. produces a constant flux, so no e.m.f. is induced.
You must show your working, substitute values into the correct equation, and give the answer with appropriate units and significant figures. For example, using V_s/V_p = N_s/N_p to find V_s.
How Students Lose Marks (Examiner Pitfalls)
Step-by-Step Worked Solutions
Question: A transformer has 200 turns on the primary coil and 50 turns on the secondary coil. The primary voltage is 230 V a.c. Calculate the secondary voltage.
- 1.Step 1: Identify given values: N_p = 200, N_s = 50, V_p = 230 V.
- 2.Step 2: Use the transformer equation: V_s/V_p = N_s/N_p, so V_s = V_p x (N_s/N_p).
- 3.Step 3: Substitute: V_s = 230 x (50/200) = 230 x 0.25 = 57.5 V.
Question: An ideal transformer steps down 240 V to 12 V. The primary current is 0.50 A. Calculate the secondary current and the power input.
- 1.Step 1: For an ideal transformer, power is conserved: V_p I_p = V_s I_s.
- 2.Step 2: Rearrange to find I_s: I_s = (V_p I_p)/V_s = (240 x 0.50)/12.
- 3.Step 3: Calculate: I_s = 120/12 = 10 A. Power input = V_p I_p = 240 x 0.50 = 120 W.