OCR · A-Level · Chemistry
Course version: H432 · Version from Sept 2017
(a) interpretation of one-way TLC chromatograms in terms of Rf values
Full specification wording
Chromatography and qualitative analysis: (a) interpretation of one-way TLC chromatograms in terms of Rf values
A one-way TLC chromatogram shows spots of separated components along a plate after a solvent has travelled up it.
- Point 2 of 14
- 4 key terms
Study notes
From the teaching notes for this specification point.
The idea
A one-way TLC chromatogram shows spots of separated components along a plate after a solvent has travelled up it. The Rf value of a component is the distance that component's spot has moved from the origin divided by the distance the solvent front has moved from the same origin, measured along the direction of travel. Because Rf is a ratio of two distances it has no units and lies between 0 and 1. A component that is strongly adsorbed stays near the origin and has a low Rf; one that moves readily with the solvent has a high Rf. Comparing the Rf of an unknown spot with that of a known standard run under the same conditions helps identify the component.
What earns the marks
- Calculates Rf as the distance moved by the spot divided by the distance moved by the solvent front, both measured from the origin.
- States that Rf values are ratios and therefore have no units.
- Recognises that an Rf value must lie between 0 and 1 for a spot on the plate.
- Uses a matching Rf value, obtained under the same conditions, to support identification of a component.
- Interprets a low Rf as a component that is strongly adsorbed and moves little from the origin.
Common mistakes and how to put them right
Divides the solvent-front distance by the spot distance.
Put it right by placing the spot distance on top and the solvent-front distance underneath.
Attaches units such as cm to an Rf value.
Put it right by stating that Rf is a ratio and is unitless.
Compares Rf values from plates run with different solvents as if directly equivalent.
Put it right by comparing only results obtained under the same conditions.
Exam tips
- Always measure both distances from the same origin line to keep the ratio valid.
- Check that your calculated Rf lies between 0 and 1 as a quick sanity check.
- When identifying a component, state that the standard must be run under the same conditions.
Try the lesson
The start of the Chromatography and qualitative analysis: (a) interpretation of one-way TLC chromatograms in terms of Rf values lesson, made from teaching notes for this specification point.
Listen
A one-way TLC chromatogram shows spots of separated components along a plate after a solvent has travelled up it. The Rf value of a component is the distance that component's spot has moved from the origin divided by the distance the solvent front has moved from the same origin, measured along the direction of travel. Because Rf is a ratio of two distances it has no units and lies between 0 and 1. A component that is strongly adsorbed stays near the origin and has a low Rf; one that moves readily with the solvent has a high Rf. Comparing the Rf of an unknown spot with that of a known standard run under the same conditions helps identify the component. A strong answer earns marks for these points. Calculates Rf as the distance moved by the spot divided by the distance moved by the solvent front, both measured from the origin. States that Rf values are ratios and therefore have no units. Recognises that an Rf value must lie between 0 and 1 for a spot on the plate. Uses a matching Rf value, obtained under the same conditions, to support identification of a component. A common slip: Divides the solvent-front distance by the spot distance. Instead, placing the spot distance on top and the solvent-front distance underneath. Exam tip: Always measure both distances from the same origin line to keep the ratio valid.
Key words
Say what each word means before you turn the card.
Rf value calculation
Try answering aloud or in your head before turning the card.
Distance from origin and solvent front
Try answering aloud or in your head before turning the card.
Identification by comparison with standards
Try answering aloud or in your head before turning the card.
Adsorption and spot position
Try answering aloud or in your head before turning the card.
See every definition
- Rf value calculation
- The distance that a component's spot has moved from the origin divided by the distance the solvent front has moved from the same origin, measured along the direction of travel.
- Distance from origin and solvent front
- Both distances are measured from the same origin line along the direction of travel to keep the ratio valid.
- Identification by comparison with standards
- Comparing the Rf of an unknown spot with that of a known standard run under the same conditions helps identify the component.
- Adsorption and spot position
- A component that is strongly adsorbed stays near the origin and has a low Rf, while one that moves readily with the solvent has a high Rf.
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of Chromatography and qualitative analysis: (a) interpretation of one-way TLC chromatograms in terms of Rf values
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge