OCR · A-Level · Chemistry

    Course version: H432 · Version from Sept 2017

    (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A…

    Full specification wording

    How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation.

    The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT +…

    • Point 18 of 18
    • 3 key terms

    Study notes

    From the teaching notes for this specification point.

    The idea

    The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT + ln A, which has the form y = mx + c with y = ln k, x = 1/T, gradient m = –Ea/R and intercept c = ln A. To find Ea and A graphically, measure k at several temperatures, convert each T to kelvin, plot ln k against 1/T, draw a line of best fit, then calculate Ea = –gradient × R and A = e^(intercept). A steeper negative gradient means a larger Ea; a higher intercept means a larger A.

    What earns the marks

    • Identifies the linear form ln k = –Ea/RT + ln A as y = mx + c with y = ln k and x = 1/T.
    • States that the gradient equals –Ea/R so Ea is found from Ea = –gradient × R.
    • States that the intercept on the ln k axis equals ln A so A is found from A = e^(intercept).
    • Explains that temperatures must be converted to kelvin before calculating 1/T.
    • Relates a steeper negative gradient to a larger activation energy for the reaction.

    Common mistakes and how to put them right

    • Plots ln k against T instead of against 1/T.

      Put it right: Use the reciprocal of temperature in kelvin so the graph is linear.

    • Forgets the negative sign and reports Ea as gradient × R.

      Put it right: Use Ea = –gradient × R because the gradient is negative.

    • Uses degrees Celsius in 1/T.

      Put it right: Convert every temperature to kelvin by adding 273 first.

    • Treats the intercept as A directly.

      Put it right: Take the exponential so A = e^(intercept).

    Exam tips

    • Write the rearranged equation and label the axes before describing the plot, so the gradient and intercept are unambiguous.
    • Show the unit of the gradient (K) and confirm Ea comes out in J mol⁻¹, converting to kJ mol⁻¹ if required.
    • Check the sign: a negative gradient with the minus sign in Ea = –gradient × R must give a positive activation energy.

    Try the lesson

    The start of the How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation. lesson, made from teaching notes for this specification point.

    Listen

    The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT + ln A, which has the form y = mx + c with y = ln k, x = 1/T, gradient m = –Ea/R and intercept c = ln A. To find Ea and A graphically, measure k at several temperatures, convert each T to kelvin, plot ln k against 1/T, draw a line of best fit, then calculate Ea = –gradient × R and A = e^(intercept). A steeper negative gradient means a larger Ea; a higher intercept means a larger A. A strong answer earns marks for these points. Identifies the linear form ln k = –Ea/RT + ln A as y = mx + c with y = ln k and x = 1/T. States that the gradient equals –Ea/R so Ea is found from Ea = –gradient × R. States that the intercept on the ln k axis equals ln A so A is found from A = e^(intercept). Explains that temperatures must be converted to kelvin before calculating 1/T. Exam tip: Write the rearranged equation and label the axes before describing the plot, so the gradient and intercept are unambiguous.

    See it

    A top-to-bottom flowchart with nine nodes. The first node says measure k at several temperatures and leads to convert each T to kelvin, which leads to calculate 1/T, which leads to plot ln k against 1/T, which leads to draw line of best fit. From the line of best fit the flow splits into two branches: one node states gradient = –Ea/R and the other states intercept = ln A. The gradient branch leads to Ea = –gradient × R, and the intercept branch leads to A = e^(intercept).
    The sequence of steps for finding Ea and A graphically from a plot of ln k against 1/T, showing how the gradient and intercept give Ea and A.

    Key words

    Say what each word means before you turn the card.

    Graphical determination of activation energy

    Try answering aloud or in your head before turning the card.

    Pre-exponential factor and intercept

    Try answering aloud or in your head before turning the card.

    Temperature in kelvin and reciprocal plots

    Try answering aloud or in your head before turning the card.

    See every definition
    Graphical determination of activation energy
    Measuring k at several temperatures, converting each T to kelvin, plotting ln k against 1/T and drawing a line of best fit, then calculating Ea = –gradient × R.
    Pre-exponential factor and intercept
    The intercept on the ln k axis equals ln A, so A is found from A = e^(intercept), and a higher intercept means a larger A.
    Temperature in kelvin and reciprocal plots
    Temperatures must be converted to kelvin before calculating 1/T, and ln k is plotted against 1/T rather than against T so the graph is linear.

    Label the diagram

    Some boxes have lost their names. Pick the right name for each number.

    The diagram again, with 3 boxes numbered instead of named. A top-to-bottom flowchart with nine nodes. The first node says measure k at several temperatures and leads to convert each T to kelvin, which leads to calculate 1/T, which leads to plot ln k against 1/T, which leads to draw line of best fit. From the line of best fit the flow splits into two branches: one node states gradient = –Ea/R and the other states intercept = ln A. The gradient branch leads to Ea = –gradient × R, and the intercept branch leads to A = e^(intercept).
    • 1Box 1

    • 2Box 2

    • 3Box 3

    0 of 3 labelled

    There is more to this lesson

    The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.

    Carry on with the full lesson

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge

    Test your understanding of How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation.

    Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.

    Take topic quiz

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge