How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation.
The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT +…
- Point 18 of 18
- 3 key terms
Study notes
From the teaching notes for this specification point.
The idea
The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT + ln A, which has the form y = mx + c with y = ln k, x = 1/T, gradient m = –Ea/R and intercept c = ln A. To find Ea and A graphically, measure k at several temperatures, convert each T to kelvin, plot ln k against 1/T, draw a line of best fit, then calculate Ea = –gradient × R and A = e^(intercept). A steeper negative gradient means a larger Ea; a higher intercept means a larger A.
What earns the marks
- Identifies the linear form ln k = –Ea/RT + ln A as y = mx + c with y = ln k and x = 1/T.
- States that the gradient equals –Ea/R so Ea is found from Ea = –gradient × R.
- States that the intercept on the ln k axis equals ln A so A is found from A = e^(intercept).
- Explains that temperatures must be converted to kelvin before calculating 1/T.
- Relates a steeper negative gradient to a larger activation energy for the reaction.
Common mistakes and how to put them right
Plots ln k against T instead of against 1/T.
Put it right: Use the reciprocal of temperature in kelvin so the graph is linear.
Forgets the negative sign and reports Ea as gradient × R.
Put it right: Use Ea = –gradient × R because the gradient is negative.
Uses degrees Celsius in 1/T.
Put it right: Convert every temperature to kelvin by adding 273 first.
Treats the intercept as A directly.
Put it right: Take the exponential so A = e^(intercept).
Exam tips
- Write the rearranged equation and label the axes before describing the plot, so the gradient and intercept are unambiguous.
- Show the unit of the gradient (K) and confirm Ea comes out in J mol⁻¹, converting to kJ mol⁻¹ if required.
- Check the sign: a negative gradient with the minus sign in Ea = –gradient × R must give a positive activation energy.
Try the lesson
The start of the How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation. lesson, made from teaching notes for this specification point.
Listen
The Arrhenius equation k = A e^(–Ea/RT) links the rate constant k to temperature T in kelvin, the activation energy Ea and the pre-exponential factor A. Taking natural logs gives ln k = –Ea/RT + ln A, which has the form y = mx + c with y = ln k, x = 1/T, gradient m = –Ea/R and intercept c = ln A. To find Ea and A graphically, measure k at several temperatures, convert each T to kelvin, plot ln k against 1/T, draw a line of best fit, then calculate Ea = –gradient × R and A = e^(intercept). A steeper negative gradient means a larger Ea; a higher intercept means a larger A. A strong answer earns marks for these points. Identifies the linear form ln k = –Ea/RT + ln A as y = mx + c with y = ln k and x = 1/T. States that the gradient equals –Ea/R so Ea is found from Ea = –gradient × R. States that the intercept on the ln k axis equals ln A so A is found from A = e^(intercept). Explains that temperatures must be converted to kelvin before calculating 1/T. Exam tip: Write the rearranged equation and label the axes before describing the plot, so the gradient and intercept are unambiguous.
See it
Key words
Say what each word means before you turn the card.
Graphical determination of activation energy
Try answering aloud or in your head before turning the card.
Pre-exponential factor and intercept
Try answering aloud or in your head before turning the card.
Temperature in kelvin and reciprocal plots
Try answering aloud or in your head before turning the card.
See every definition
- Graphical determination of activation energy
- Measuring k at several temperatures, converting each T to kelvin, plotting ln k against 1/T and drawing a line of best fit, then calculating Ea = –gradient × R.
- Pre-exponential factor and intercept
- The intercept on the ln k axis equals ln A, so A is found from A = e^(intercept), and a higher intercept means a larger A.
- Temperature in kelvin and reciprocal plots
- Temperatures must be converted to kelvin before calculating 1/T, and ln k is plotted against 1/T rather than against T so the graph is linear.
Label the diagram
Some boxes have lost their names. Pick the right name for each number.
1Box 1
2Box 2
3Box 3
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of How fast?: (ii) determination of Ea and A graphically using: ln k = –Ea/RT + ln A derived from the Arrhenius equation.
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge