OCR · A-Level · Chemistry

    Course version: H432 · Version from Sept 2017

    (g) the techniques and procedures used for the measurement of cell…

    Full specification wording

    Redox and electrode potentials: (g) the techniques and procedures used for the measurement of cell potentials of:

    Measuring a cell potential means building a cell from two half-cells, each dipping into its own solution, joined by a salt bridge (often filter paper soaked in potassium nitrate) that completes…

    • Point 8 of 14
    • 3 key terms

    Study notes

    From the teaching notes for this specification point.

    The idea

    Measuring a cell potential means building a cell from two half-cells, each dipping into its own solution, joined by a salt bridge (often filter paper soaked in potassium nitrate) that completes the circuit without mixing the solutions. Clean metal electrodes are dipped into solutions of their own ions at known concentration; where a half-cell has no metal, platinum is used. A high-resistance voltmeter connects the two electrodes and reads the e.m.f. under near-zero current so the cell is close to equilibrium. Standard conditions (298 K, 1 mol dm⁻³ solutions, 100 kPa gases) give E⦵cell. The reading is the difference between the two electrode potentials, with the more positive couple on the right.

    What earns the marks

    • Describes joining two half-cells with a salt bridge that completes the circuit while keeping the solutions separate.
    • Specifies clean electrodes dipped in solutions of their own ions at known concentration, with platinum where no metal is present.
    • States that a high-resistance voltmeter is used so the cell is measured under near-zero current.
    • Applies standard conditions of 298 K, 1 mol dm⁻³ and 100 kPa to obtain E⦵cell.
    • Explains that the measured cell potential is the difference between the two electrode potentials, with the more positive couple written on the right.

    Common mistakes and how to put them right

    • Uses a low-resistance ammeter or ordinary voltmeter.

      Put it right: Use a high-resistance voltmeter to avoid drawing current.

    • Lets the two solutions mix instead of using a salt bridge.

      Put it right: Keep them separate with a salt bridge.

    • Omits platinum where a half-cell has no metal electrode.

      Put it right: Include an inert platinum electrode.

    • Ignores standard conditions and reports a non-standard reading as E⦵cell.

      Put it right: Apply 298 K, 1 mol dm⁻³ and 100 kPa.

    Exam tips

    • Draw and label the apparatus: two half-cells, salt bridge, high-resistance voltmeter and electrodes.
    • State the standard conditions explicitly before quoting a value as E⦵cell.
    • Identify which couple is more positive to decide the cell direction and sign.

    Try the lesson

    The start of the Redox and electrode potentials: (g) the techniques and procedures used for the measurement of cell potentials of: lesson, made from teaching notes for this specification point.

    Listen

    Measuring a cell potential means building a cell from two half-cells, each dipping into its own solution, joined by a salt bridge (often filter paper soaked in potassium nitrate) that completes the circuit without mixing the solutions. Clean metal electrodes are dipped into solutions of their own ions at known concentration; where a half-cell has no metal, platinum is used. A high-resistance voltmeter connects the two electrodes and reads the e.m.f. under near-zero current so the cell is close to equilibrium. Standard conditions (298 K, 1 mol dm⁻³ solutions, 100 kPa gases) give E⦵cell. The reading is the difference between the two electrode potentials, with the more positive couple on the right. A strong answer earns marks for these points. Describes joining two half-cells with a salt bridge that completes the circuit while keeping the solutions separate. Specifies clean electrodes dipped in solutions of their own ions at known concentration, with platinum where no metal is present. States that a high-resistance voltmeter is used so the cell is measured under near-zero current. Applies standard conditions of 298 K, 1 mol dm⁻³ and 100 kPa to obtain E⦵cell. Exam tip: Draw and label the apparatus: two half-cells, salt bridge, high-resistance voltmeter and electrodes.

    Key words

    Say what each word means before you turn the card.

    Salt bridge function

    Try answering aloud or in your head before turning the card.

    High-resistance voltmeter

    Try answering aloud or in your head before turning the card.

    Standard conditions and cell e.m.f.

    Try answering aloud or in your head before turning the card.

    See every definition
    Salt bridge function
    A salt bridge, often filter paper soaked in potassium nitrate, completes the circuit without mixing the solutions.
    High-resistance voltmeter
    A high-resistance voltmeter connects the two electrodes and reads the e.m.f. under near-zero current so the cell is close to equilibrium.
    Standard conditions and cell e.m.f.
    Standard conditions of 298 K, 1 mol dm⁻³ solutions and 100 kPa gases give E⦵cell.

    There is more to this lesson

    The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.

    Carry on with the full lesson

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge

    Test your understanding of Redox and electrode potentials: (g) the techniques and procedures used for the measurement of cell potentials of:

    Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.

    Take topic quiz

    A week of Premium from your first lesson · Then the free plan continues · No card, no charge