    1. PAG B1 Microscopy

      Microscopy measurements use an eyepiece graticule calibrated against a stage micrometer of known scale, giving the true value of each graticule division at a stated objective. Actual size is found from actual size = image size / magnification (A = I / M), with all lengths in the same unit; convert mm to micrometres and micrometres to nanometres by multiplying by 1000. Repeating measurements on several randomly selected cells and calculating a mean reduces the effect of natural variation. The same practical skills cover other quantities: area by counting squares or using length x width, mass with a balance, time with a stopwatch, temperature with a thermometer, liquid volume with a measuring cylinder, gas volume by displacement or a syringe, and pH with a calibrated pH probe (universal indicator gives an approximate value).

      Go to Microscopy
    2. PAG B2 Testing for biological molecules

      Qualitative reagents identify macromolecules in food and track digestive breakdown. Benedict's reagent tests for reducing sugars, turning from blue through green, yellow and orange to brick-red precipitate on heating, depending on concentration. Iodine solution tests for starch, changing from yellow-brown to blue-black. Biuret reagent tests for proteins, changing from pale blue to lilac or purple. The emulsion test with ethanol and water identifies lipids, forming a white milky emulsion. In continuous sampling, such as amylase breaking down starch, aliquots are removed at fixed intervals, for example every 30 seconds, and added to iodine drops on a spotting tile until the mixture stays yellow-brown, showing the end point of starch digestion.

      Go to Testing for biological molecules
    3. PAG B3 Sampling techniques

      Accurate field investigations depend on calibrated instruments to measure abiotic variables alongside biological data. Transect tape measures record horizontal distance (length in metres), while quadrat frames define known sampling boundaries (area in square metres). Digital lux meters measure incident light intensity at ground level without shading the sensor. Digital soil thermometers measure temperature at consistent depths. Soil pH is determined using calibrated electronic probes or universal indicator chemical extraction kits. Soil moisture is measured with electronic resistance probes or gravimetrically: collect a soil core, weigh its initial mass, dry in an oven to constant mass, then calculate percentage water loss. Repeats at each station help identify anomalous readings, though they cannot eliminate all random error.

      Go to Sampling techniques
    4. PAG B4 Rates of enzyme-controlled reactions

      Enzyme reaction rates can be measured by several methods. Gas production: catalase breaks down hydrogen peroxide, releasing oxygen collected in a gas syringe or over water in an inverted measuring cylinder at timed intervals; rate = volume of gas ÷ time (cm³ s⁻¹). Uptake of water: in a respirometer, carbon dioxide produced by respiring yeast is absorbed by an alkali such as potassium hydroxide, so the gas volume falls and water is drawn in to replace it; the distance the water droplet moves per unit time gives the rate. Colour change of indicator: time amylase to digest starch until iodine no longer turns blue-black, or time trypsin clearing milk suspension against a printed cross; rate = 1 ÷ time to end point. Initial rate is found from the tangent to the steepest part of a product-time curve.

      Go to Rates of enzyme-controlled reactions
    5. PAG B5 Photosynthesis

      Photosynthetic rates can be quantified using bubble counting, volumetric gas collection, water uptake, or indicator colorimetry. Counting bubbles released per minute from pondweed is simple but error-prone because bubble volume varies and rapid bubbling is hard to count accurately. A photosynthometer or inverted microburette collects oxygen into a capillary tube, where the length of the gas bubble is measured with a millimetre ruler or syringe to calculate exact volume. Uptake of water can be measured with an aquatic potometer: as photosynthesis proceeds, water is drawn along a capillary and the meniscus movement per minute is recorded as a rate. Alternatively, hydrogencarbonate indicator enclosing pondweed or immobilised algae balls changes from red to purple as carbon dioxide is absorbed, providing a colorimetric measure of photosynthetic rate.

      Go to Photosynthesis
    6. PAG B6 Physiology, responses respiration

      Measuring respiration and behavioral responses in living organisms (such as germinating seeds, yeast, woodlice, or maggots) requires strict ethical protocols. In choice chamber assays investigating taxis responses to light or humidity, invertebrates must be transferred gently using a soft paintbrush or specimen spoon to avoid mechanical trauma. Organisms must never be exposed to lethal temperatures, bright heat lamps, or dehydrating conditions, and must be returned to their natural damp habitat immediately following the experiment. In respirometer setups, invertebrates must be protected from direct contact with corrosive chemical carbon dioxide absorbents (such as soda lime pellets) by a secure wire mesh barrier.

      Go to Physiology, responses respiration
    7. PAG B7 Microbiological techniques

      Safe heating underpins aseptic technique. A roaring blue Bunsen flame creates an upward convection current; working within about 20 cm of it prevents airborne microbes settling on open agar plates. Metal inoculating loops are flamed to red heat along their length and air-cooled before transferring bacteria, and culture bottle necks are passed briefly through the flame on opening and before recapping. A water bath or electric heater provides a controlled, flameless heat source for incubating cultures or melting cooled agar at a set temperature, avoiding the risk of overheating or igniting flammable materials. In school laboratories, inoculated petri dishes are taped with two pieces of adhesive tape (not sealed completely airtight) and incubated inverted at a maximum of 25 °C to prevent pathogen growth.

      Go to Microbiological techniques
    8. PAG B8 Transport in and out of cells

      Osmosis is investigated by tracking mass changes in plant tissue (such as potato cylinders) immersed in a range of sucrose concentrations (e.g. 0.0, 0.2, 0.4, 0.6, 0.8, and 1.0 mol/dm³). Cylinders are excised using a cork borer and trimmed to equal lengths on a ceramic tile using a scalpel. Cylinders are weighed on a two-decimal-place electronic balance before immersion. After incubating in sealed boiling tubes for at least 45 minutes, cylinders are removed, rolled gently on a paper towel to remove surface water without squeezing tissue, and reweighed. Percentage change in mass is calculated: ((final mass - initial mass) / initial mass) multiplied by 100, accounting for variation in initial cylinder sizes.

      Go to Transport in and out of cells